Showing results: 721 - 735 of 916 items found.
-
MWH-10A -
Chuan Sheng Electronics Co., Ltd.
MWH-10A Energy Meter offers high accuracy measurements of Energy (Watt-Hr) and Active Power, display and communication functions. It is also with 1 relay output, 1 analogue output, 1 RS485 communication port, and 1 pulse output in option as well 112mm (D) is ideal for assembling in panels with limited penetration depth.
-
CMC 353 -
OMICRON electronics
With its compact design and low weight of 13.3 kg / 29.3 lbs, the CMC 353 provides the perfect combination of portability and power. It is the ideal test set for three-phase protection testing and the commissioning of SCADA systems. The powerful current outputs (3 x 32 A / 430 VA) optimally support 5 A relay testing.
-
ENVIROMUX-16D -
Network Technologies Inc
The ENVIROMUX-16D supports 16 external configurable sensors, 8 digital inputs, and 4 output relays for control of external devices. The system also includes three internal sensors: temperature, humidity and power. It features 4 USB ports for USB modem, USB flash drive, or USB LCD screen. Linux inside.
-
NI
The PXI System Monitoring Module can be used with a PXI Chassis to detect and report chassis voltage rail problems, abnormal chassis intake temperature, or a chassis power shuttle fan failure. The PXI System Monitoring Module also includes a relay that can toggle when any of the parameters fall outside the chassis operating specification.
-
40-185 -
CTEK Power USA
SMARTPASS 120 is a fully automatic 120A power management system that prioritizes, controls and maximizes energy from your alternator to power your service battery. It safely separates your starter and service batteries automatically. It also distributes power between the starter battery, the service battery and on board equipment without the need for traditional diodes or VSR relays. This means that SMARTPASS 120 can make sure that critical functions like starters, radios, emergency lights and communication systems always have the power they need, and take priority over noncritical functions. SMARTPASS 120 works with any 12V lead acid battery. It can also be used with the CTEK D250SA 20A on board charger for the ultimate 140A power management system.
-
Series 60 & 65 -
Pickering Electronics
High voltage relays - chassis mounted, up to 15kV. Tungsten switches with power rating of 50 Watts maximum. Series 60 has solder terminals and nylon chassis mounting studs
-
AK-10 -
Amperis sl
The new AK-10 three-phase relay test equipment from Amperis features AC and DC Voltage Source ; AC Current Source ; AC/DC Auxiliary Power Source ; 8 possible configurations.
-
YAV90086 -
6TL Engineering
16 power relays SPST Switching up to 2770VA 16A Switching 125Vac 10A Switching 277Vac CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Neutronics Manufacturing Co.
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Neutronics Manufacturing Co.
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Neutronics Manufacturing Co.
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Laplace Instruments Ltd.
Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.
-
Omron Industrial Automation
As well as being slim and thus saving panel space, The relays are very strong, have a large contact area and non-bendable pins. Connection to a PLC is easy and achieved faultlessly in a few seconds via click connectors. In addition, power switching in G3RV relays with DC outputs is managed by a MOSFET in the output, which has ideal heat dissipation characteristics.
-
SCP1000/SCP2000 -
Electro-Sensors, Inc.
Features• Internal sensor• Over-or under-speed config., 1-990 rpm• 1 DPDT relay output (SCP1000), 2 SPDT relay outputs (SCP2000)• Built-in start delay• Dial-in calibration does not require power• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Works with Electro-Sensors magnetic pulser discs / wraps• Explosion proof housing• UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Insight Product Company
Travelling wave tubes remains a valuable type of amplifier for high output power in the microwave range. Its main advantages are of high output power, big bandwidth-duration and reliability. Insight Product Co. offers TWT packaged tubes providing output power from tens to several hundred watt in a continuous mode and to 1.5-2.0 kw in a pulse mode, and frequency bandwidth of 1.5 octaves. TWT applications include satelite communications (transponders) both on land and on satelite installations, radio relay communication lines, electromagnetic compatability (EMC) testing industry for immunity testing of electronic devices, and radars (maritime, weather, airplanes, land).